TNDT logo
THAI NONDESTRUCTIVE TESTING
PUBLIC COMPANY LIMITED

www.tndt.co.th
ULTRASONIC TESTING / ENGINEERING TOOLS / REV.05

PAUT Acceptance Criteria Evaluation

01 / Flaw input · ข้อมูลรอยบกพร่อง

All dimensions in mm. S = shortest ligament to either surface. For an actual surface-connected flaw, enter S = 0.

02 / Flaw geometry · รูปแบบรอยบกพร่อง

03 / Evaluation result · ผลประเมิน

04 / Reference and limitations

Tables E-3-1, E-3-2, E-3-3; E-7(a–c); E-8(a–d); Figure E-7-1. This prototype evaluates one isolated flaw using the metric table values. Multiple-flaw interaction requires Figures E-7-2 through E-7-5, not supplied. The optional 6.4 mm length provision in Table E-3-2 note (c) is not automatically applied; marginal results require review. Surface-classified indications require E-8(c) verification. No extrapolation outside tabulated aspect ratios.

Engineering review required before production use; procedure qualification, examination coverage and personnel qualification are outside this calculator.